Use Nightscout during a clinic appointment
Use Nightscout as a shared record with known coverage. Do not assume every record type or every minute of data is present.
Review workflow
- Confirm the correct person, units and timezone, and the source app/device.
- Check freshness and continuity before drawing conclusions. Identify periods when the source, uploader or follower was offline.
- Open Menu → Reports and use the report walkthrough for the agreed date range.
- Compare the glucose trace with treatments only where the source provides those records. A glucose-only connector cannot establish whether insulin or carbohydrates were absent.
- Review profile effective dates if calculations depend on a profile. Device IOB and Nightscout-calculated IOB may use different models.
- Save a report through the approved clinical workflow and document missing-data limitations alongside the review.
Nightscout summary metrics depend on selected dates, filters and data quality. Estimated A1c/GMI figures are not laboratory measurements. Treatment decisions should use the clinician’s established assessment and the relevant device/care guidance.
For a data-quality problem, ask support about the specific date/type/source rather than modifying treatment records to make a report appear complete. Interpretation checks.